Lower limb sagittal kinematic and kinetic modeling of very slow walking for gait trajectory scaling

下肢矢状面运动学和动力学建模用于极慢步态轨迹缩放

阅读:1

Abstract

Lower extremity powered exoskeletons (LEPE) are an emerging technology that assists people with lower-limb paralysis. LEPE for people with complete spinal cord injury walk at very slow speeds, below 0.5m/s. For the able-bodied population, very slow walking uses different neuromuscular, locomotor, postural, and dynamic balance control. Speed dependent kinetic and kinematic regression equations in the literature could be used for very slow walking LEPE trajectory scaling; however, kinematic and kinetic information at walking speeds below 0.5 m/s is lacking. Scaling LEPE trajectories using current reference equations may be inaccurate because these equations were produced from faster than real-world LEPE walking speeds. An improved understanding of how able-bodied people biomechanically adapt to very slow walking will provide LEPE developers with more accurate models to predict and scale LEPE gait trajectories. Full body motion capture data were collected from 30 healthy adults while walking on an instrumented self-paced treadmill, within a CAREN-Extended virtual reality environment. Kinematic and kinetic data were collected for 0.2 m/s-0.8 m/s, and self-selected walking speed. Thirty-three common sagittal kinematic and kinetic gait parameters were identified from motion capture data and inverse dynamics. Gait parameter relationships to walking speed, cadence, and stride length were determined with linear and quadratic (second and third order) regression. For parameters with a non-linear relationship with speed, cadence, or stride-length, linear regressions were used to determine if a consistent inflection occurred for faster and slower walking speeds. Group mean equations were applied to each participant's data to determine the best performing equations for calculating important peak sagittal kinematic and kinetic gait parameters. Quadratic models based on walking speed had the strongest correlations with sagittal kinematic and kinetic gait parameters, with kinetic parameters having the better results. The lack of a consistent inflection point indicated that the kinematic and kinetic gait strategies did not change at very slow gait speeds. This research showed stronger associations with speed and gait parameters then previous studies, and provided more accurate regression equations for gait parameters at very slow walking speeds that can be used for LEPE joint trajectory development.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。