Sensor-Based Frailty Assessment Using Fitbit

基于 Fitbit 的传感器衰弱评估

阅读:3

Abstract

This study evaluated the reliability of Fitbit in assessing frailty based on motor and heart rate (HR) parameters through a validated upper extremity function (UEF) test, which involves 20 s of rapid elbow flexion. For motor performance, participants completed six trials of full elbow flexion using their right arm, with and without weight. Fitbit and a commercial motion sensor were worn on the right arm. For HR measurements, an ECG system was placed on the left chest alongside the Fitbit on the left wrist. Motor parameters assessing speed, flexibility, weakness, exhaustion, and HR before, during, and after UEF were measured. A total of 42 participants (age = 22 ± 3) were recruited. For motor parameters, excellent agreement was observed between the wearable sensor and Fitbit, except for flexibility (ICC = 0.87 ± 0.09). For HR parameters, ICC values showed weak agreement between ECG and Fitbit for HR increase and recovery (ICC = 0.24 ± 0.11), while moderate to stronger agreement was seen for mean HR during baseline, task, and post-task (ICC = 0.81 ± 0.13). Fitbit is a reliable tool for assessing frailty through motor parameters and provides reasonably accurate HR estimates during baseline, task, and recovery periods. However, Fitbit's ability to track rapid HR changes during activity is limited.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。