Assessment of autostereoscopic perception using artificial intelligence-enhanced face tracking technology

利用人工智能增强型面部追踪技术评估自动立体感知

阅读:1

Abstract

PURPOSE: Stereopsis, the ability of humans to perceive depth through distinct visual stimuli in each eye, is foundational to autostereoscopic technology in computing. However, ensuring stable head position during assessments has been challenging. This study evaluated the utility of artificial intelligence (AI)-enhanced face tracking technology in overcoming this challenge by ensuring that each eye consistently receives its intended image. METHODS: The Lume Pad 2, an autostereoscopic tablet with AI-enhanced face tracking, was utilized to simulate quantitative parts of the Stereo Fly test and TNO Stereotests for contour and random dot stereopsis. The study recruited 30 children (14 males and 16 females, mean age of 9.2 ± 0.3 years, age range of 6-12 years) and 30 adults (10 males and 20 females, mean age of 29.4 ± 1.0 years, age range of 21-42 years) to assess the tablet's inter-session reliability. Agreement between conventional and the autostereoscopic tablet-simulated stereotests was tested in a larger group of 181 children (91 males and 90 females, mean age of 9.1 ± 0.4 years, age range of 6-12 years) and 160 adults (69 males and 91 females, mean age of 38.6 ± 2.1 years, age range of 21-65 years). Inter-session reliability and agreement were analyzed using weighted Kappa coefficient and non-parametric Bland-Altman analysis. RESULTS: The autostereoscopic tablet demonstrated high inter-session reliability (κ all > 0.80), except for the simulated TNO Stereotest in adults, which demonstrated moderate inter-session reliability (κ = 0.571). Non-parametric Bland-Altman analysis revealed zero median differences, confirming consistent inter-session reliability. Similar patterns were observed in comparing AI-based and conventional methods, with both the weighted Kappa coefficient (κ all > 0.80) and non-parametric Bland-Altman analysis indicating significant agreement. The agreement between methodologies was confirmed by permissible differences, which were smaller than the minimum step range. CONCLUSION: The integration of AI-based autostereoscopic technology with sub-pixel precision demonstrates significant potential for clinical stereopsis measurements.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。