Path-Planning System for Radioisotope Identification Devices Using 4π Gamma Imaging Based on Random Forest Analysis

基于随机森林分析的4π伽马成像放射性同位素识别装置路径规划系统

阅读:1

Abstract

We developed a path-planning system for radiation source identification devices using 4π gamma imaging. The estimated source location and activity were calculated by an integrated simulation model by using 4π gamma images at multiple measurement positions. Using these calculated values, a prediction model to estimate the probability of identification at the next measurement position was created by via random forest analysis. The path-planning system based on the prediction model was verified by integrated simulation and experiment for a (137)Cs point source. The results showed that (137)Cs point sources were identified using the few measurement positions suggested by the path-planning system.