High-Precision Calibration Technology and Experimental Verification for Dual-Axis Laser Communication Systems

双轴激光通信系统的高精度校准技术及实验验证

阅读:1

Abstract

With the continuous improvement of remote sensing satellite resolution, laser communication technology has gained significant traction. The pointing accuracy of ground-based laser communication terminals is critical for the stability of satellite-ground laser transmission links. To enhance the pointing accuracy of ground-based laser communication terminals, this study proposes a high-precision calibration methodology utilizing an error correction mathematical model. This approach complements traditional methods. The pointing errors of an alt-azimuth dual-axis laser communication terminal system are analyzed, and the principles and implementation processes of the error correction mathematical model are presented. Calibration experiments were conducted using an existing laser communication terminal test platform. Observation error data were obtained by comparing stellar observations with theoretical stellar positions, and error model parameters were fitted. Verification through stellar observations after model establishment and error correction showed that the mean open-loop pointing error can be controlled to approximately 5″ or less. Compared to traditional methods, accuracy can be improved by over 85%, demonstrating significant and highly accurate error correction effects and validating the proposed method.