Resolving inter-crystal scatter in a light-sharing depth-encoding PET detector

解决光共享深度编码PET探测器中的晶体间散射问题

阅读:1

Abstract

Objective.Inter-crystal scattering (ICS) in light-sharing positron emission tomography (PET) detectors leads to ambiguity in positioning the initial interaction, which significantly degrades the contrast, quantitative accuracy, and spatial resolution of the resulting image. Here, we attempt to resolve the positioning ambiguity of ICS in a light-sharing depth-encoding detector by exploiting the confined, deterministic light-sharing enabled by the segmented light guide unique to Prism-PET.Approach.We first considered a test case of ICS between two adjacent crystals using an analytical and a neural network approach. The analytical approach used a Bayesian estimation framework constructed from a scatter absorption model-the prior-and a detector response model-the likelihood. A simple neural network was generated for the same scenario, to provide mutual validation for the findings. Finally, we generalized the solution to three-dimensional event positioning that handles all events in the photopeak using a convolutional neural network with unique architecture that separately predicts the identity and depth-of-interaction (DOI) of the crystal containing the first interaction.Main results.The analytical Bayesian method generated an estimation error of 20.5 keV in energy and 3.1 mm in DOI. Further analysis showed that the detector response model was sufficiently robust to achieve adequate performance via maximum likelihood estimation (MLE), without prior information. We then found convergent results using a simple neural network. In the generalized solution using a convolutional neural network, we found crystal identification accuracy of 83% and DOI estimation error of 3.0 mm across all events. Applying this positioning algorithm to simulated data, we demonstrated significant improvements in image quality over the baseline, centroid-based positioning approach, attaining 38.9% improvement in intrinsic spatial resolution and enhanced clarity in hot spots of diameters 0.8 to 2.5 mm.Significance.The accuracy of our findings exceeds those of previous reports in the literature. The Prism-PET light guide, mediating confined and deterministic light-sharing, plays a key role in ICS recovery, as its mathematical embodiment-the detector response model-was the essential driver of accuracy in our results.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。