Model-based monitoring of diffuser fouling using standard sensors

基于模型的标准传感器对扩散器结垢情况进行监测

阅读:2

Abstract

Fouling of fine-pore diffusers can cause substantial aeration energy wastage. It remains challenging to monitor their condition and decide the optimal time for labour-intensive and costly cleaning actions. In this study, we show that data from standard sensors (airflow rate, dissolved oxygen concentration, pressure and airflow valve position), which are fed to simple models, can track the diffuser's condition. Additionally, the parameter estimation of diffuser dynamic wet pressure, oxygen transfer rate, respiration rate and the joint alpha fouling factor (αF) was facilitated by an active fault detection inspired method. The method executes a sequence with piecewise constant valve positions via the control system. As a result, airflow rates in a sequence similar to a staircase are obtained, which simplifies the estimation of dissolved oxygen dynamics and airflow rate dynamics. The proposed method was evaluated on a full scale over 18 months and successfully detected a reduced cleaning in the diffusers and several sensor-related disturbances. Ultimately, the findings motivate further research on how modelling combined with repetitive process disturbances can leverage data-driven insights from standard instrumentation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。