Real World Interstitial Glucose Profiles of a Large Cohort of Physically Active Men and Women

一项针对大量积极运动的男性和女性的真实世界组织间液葡萄糖谱研究

阅读:1

Abstract

The use of continuous glucose monitors (CGMs) in individuals living without diabetes is increasing. The purpose of this study was to profile various CGM metrics around nutritional intake, sleep and exercise in a large cohort of physically active men and women living without any known metabolic disease diagnosis to better understand the normative glycemic response to these common stimuli. A total of 12,504 physically active adults (age 40 ± 11 years, BMI 23.8 ± 3.6 kg/m(2); 23% self-identified as women) wore a real-time CGM (Abbott Libre Sense Sport Glucose Biosensor, Abbott, USA) and used a smartphone application (Supersapiens Inc., Atlanta, GA, USA) to log meals, sleep and exercise activities. A total of >1 M exercise events and 274,344 meal events were analyzed. A majority of participants (85%) presented an overall (24 h) average glucose profile between 90 and 110 mg/dL, with the highest glucose levels associated with meals and exercise and the lowest glucose levels associated with sleep. Men had higher mean 24 h glucose levels than women (24 h-men: 100 ± 11 mg/dL, women: 96 ± 10 mg/dL). During exercise, the % time above >140 mg/dL was 10.3 ± 16.7%, while the % time <70 mg/dL was 11.9 ± 11.6%, with the remaining % within the so-called glycemic tight target range (70-140 mg/dL). Average glycemia was also lower for females during exercise and sleep events (p < 0.001). Overall, we see small differences in glucose trends during activity and sleep in females as compared to males and higher levels of both TAR and TBR when these active individuals are undertaking or competing in endurance exercise training and/or competitive events.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。