Results at the 1-Year Follow-Up of a Prospective Cohort Study with Short, Zirconia Implants

一项前瞻性队列研究对短氧化锆种植体进行1年随访的结果

阅读:1

Abstract

The objective of this study was to clinically and radiologically evaluate the performance of a short (8 mm), 1-piece, zirconia implant after an observation period of 1 year in function. A total of 47 patients with 1 missing tooth in the position of a premolar or molar were recruited. Short (8 mm), 1-piece, zirconia implants were placed and loaded after a healing period of 2 to 4 months with monolithic crowns made of 3 different materials. Implants were followed up for one year and clinically and radiologically assessed. A total of 46 implants were placed. One was excluded since no primary stability was achieved at implant placement. At the 1-year follow-up, mean marginal bone loss 1 year after loading was 0.05 ± 0.47 mm. None of the implants showed marginal bone loss greater than 1 mm or clinical signs of peri-implantitis. A total of 2 implants were lost during the healing phase and another after loading, resulting in a survival rate of 93% after 1 year. All lost implants showed a sudden increased mobility with no previous signs of marginal bone loss or peri-implant infection. The short, 8 mm, zirconia implants showed stable marginal bone levels over the short observation period of 1 year. Although they revealed slightly lower survival rates, they can be suggested for the use in sites with reduced vertical bone. Scientific data are very limited, and long-term data are not yet available, and therefore, they are needed.