A Transformer-Based Approach to Leakage Detection in Water Distribution Networks

基于变压器的供水管网泄漏检测方法

阅读:1

Abstract

The efficient detection of leakages in water distribution networks (WDNs) is crucial to ensuring municipal water supply safety and improving urban operations. Traditionally, machine learning methods such as Convolutional Neural Networks (CNNs) and Autoencoders (AEs) have been used for leakage detection. However, these methods heavily rely on local pressure information and often fail to capture long-term dependencies in pressure series. In this paper, we propose a transformer-based model for detecting leakages in WDNs. The transformer incorporates an attention mechanism to learn data distributions and account for correlations between historical pressure data and data from the same time on different days, thereby emphasizing long-term dependencies in pressure series. Additionally, we apply pressure data normalization across each leakage scenario and concatenate position embeddings with pressure data in the transformer model to avoid feature misleading. The performance of the proposed method is evaluated by using detection accuracy and F1-score. The experimental studies conducted on simulated pressure datasets from three different WDNs demonstrate that the transformer-based model significantly outperforms traditional CNN methods.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。