Incidence of pulmonary vein stenosis in two types of cryoballoon systems

两种冷冻球囊系统中肺静脉狭窄的发生率

阅读:2

Abstract

BACKGROUND: Currently, two types of cryoballoon (CB) systems are available for catheter ablation of atrial fibrillation (AF). Since the POLARx (Boston Scientific) is softer during freezing than the Arctic Front Advance Pro (AFA-Pro; Medtronic), it tends to go more deeply into the pulmonary vein (PV), risking PV stenosis. METHODS: Ninety-one patients underwent initial CB ablation for paroxysmal AF (AFA-Pro 56; POLARx 35). Twenty-six from each group were extracted using propensity score matching. The PV cross-sectional area (PVA) was measured by tracing the area within the PV plane at 5-mm intervals from the PV ostium in a distal direction for 20 mm or to the bifurcation in each PV. The PVA was compared before and 3 months after ablation. RESULTS: Time to balloon temperatures of -30 and - 40°C was significantly shorter and the nadir temperature was significantly lower with POLARx than with AFA-Pro. In the left inferior (LI) PV and right superior (RS) PV, the freezing balloon position was significantly deeper in POLARx than in AFA-pro. The freezing position in RSPV with mild to moderate narrowing was deeper than those without (10.2 ± 3.3 mm vs. 8.2 ± 1.8 mm, p = .01). In RSPV, the reduction of PVA tended to be greater with the POLARx than with the AFA-Pro (26.1% ± 14.1% vs. 19.9% ± 10.3%, p = .07). CONCLUSION: There was no significant difference in the incidence of PV stenosis between POLARx and AFA-Pro. However, if POLARx goes deep into the PVs, we will still have to be careful.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。