OBJECTIVE: To develop and assess the value and limitations of an image quality scoring criteria (IQSC) for pediatric CT exams. METHODS: IQSC was developed for subjective assessment of image quality using the scoring scale from 0 to 4, with 0 indicating desired anatomy or features not seen, 3 for adequate image quality, and 4 depicting higher than needed image quality. Pediatric CT examinations from 30 separate patients were selected, five each for routine chest, routine abdomen, kidney stone, appendicitis, craniosynostosis, and ventriculoperitoneal (VP) shunt. Five board-certified pediatric radiologists independently performed image quality evaluation using the proposed IQSC. The kappa statistics were used to assess the interobserver variability. RESULTS: All five radiologists gave a score of 3 to two-third (67%) of all CT exams, followed by a score of 4 for 29% of CT exams, and 2 for 4% exams. The median image quality scores for all exams were 3 and the interobserver agreement among five readers (acceptable image quality [scores 3 or 4] vs sub-optimal image quality ([scores 1 and 2]) was moderate to very good (kappa 0.4-1). For all five radiologists, the lesion detection was adequate for all CT exams. CONCLUSIONS: The image quality scoring criteria covering routine and some clinical indication-based imaging scenarios for pediatric CT examinations has potential to offer a simple and practical tool for assessing image quality with a reasonable degree of interobserver agreement. A more extensive and multi-centric study is recommended to establish wider usefulness of these criteria.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。