Role of intrarenal resistive index and ElastPQ® renal shear modulus in early diagnosis and follow-up of diabetic nephropathy: A prospective study

肾内阻力指数和 ElastPQ® 肾剪切模量在糖尿病肾病早期诊断和随访中的作用:一项前瞻性研究

阅读:2

Abstract

INTRODUCTION: We aimed to establish baseline normal values of ElastPQ(®) (Philips Healthcare, Bothell, Washington, USA) renal shear modulus, evaluate changes in intrarenal resistive index and renal shear modulus in various stages of diabetic nephropathy, their diagnostic potential and role in follow-up. METHODS: Our prospective observational study was performed over two years. In total, 130 adult cases with diabetic nephropathy and 130 normal adult controls were selected. Diabetic nephropathy was confirmed by persistent albuminuria on 24-hour urinary albumin testing at three month intervals and staged by albuminuria quantification. Measurement of intrarenal resistive index and renal shear modulus in all subjects was performed and their variation with stage of nephropathy was statistically analyzed using Pearson's correlation. Receiver operating characteristic curves were plotted and their individual and combined diagnostic potentials were assessed. Statistical significance was tested using t tests and analysis of variance. Interrater agreement was tested using Cohen's kappa coefficient. RESULTS: Mean intrarenal resistive index was significantly higher for cases (mean 0.72 ± 0.05) than controls (mean 0.62 ± 0.04) and showed significant age variation (p < 0.05). Normal values of ElastPQ(®) renal shear modulus ranged from 3.87 to 4.72 kPa and was significantly higher for cases (mean 8.59 ± 1.77 kPa) than controls (mean 4.32 ± 0.45 kPa) and showed significant differences between each stage of nephropathy, being highest in stage 2. Maximum diagnostic accuracy was at 0.65 (sensitivity 90%, specificity 76.2%, area under curve 0.916) for intrarenal resistive index and at 5.31 kPa (sensitivity 90.8%, specificity 84.6%, area under curve 0.923) for renal shear modulus. Combination of the two further improved diagnostic performance (highest accuracy of 89%, sensitivity 81.7%, specificity 96.3%). CONCLUSIONS: Normal range of ElastPQ(®) renal shear modulus values could be established. Intrarenal resistive index and renal shear modulus can be used as imaging parameters for early diagnosis and follow-up of diabetic nephropathy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。