Inactivation of airborne bacteria using different UV sources: Performance modeling, energy utilization, and endotoxin degradation

使用不同的紫外线源灭活空气中的细菌:性能建模、能量利用和内毒素降解

阅读:6
作者:Can Wang, Siyi Lu, Zhiwei Zhang

Abstract

Airborne bacteria-containing bioaerosols have attracted increased research attention on account of their adverse effects on human health. Ultraviolet germicidal irradiation (UVGI) is an effective method to inactivate airborne microorganisms. The present study models and compares the inactivation performance of three UV sources in the UVGI for aerosolized Escherichia coli. Inactivation efficiency of 0.5, 2.2 and 3.1 logarithmic order was obtained at an exposure UV dose of 370 J/m3 under UVA (365 nm), UVC (254 nm) and UVD (185 nm) sources, respectively. A Beer-Lambert law-based model was developed and validated to compare the inactivation performances of the UV sources, and modeling enabled prediction of inactivation efficiency and analysis of the sensitivity of several parameters. Low influent E. coli concentrations and high UV doses resulted in high energy consumption (EC). The change in airborne endotoxin concentration during UV inactivation was analyzed, and UVC and UVA irradiation showed no marked effect on endotoxin degradation. By contrast, both free and bound endotoxins could be removed by UVD treatment, which is attributed to the ozone generated by the UVD source. The results of this study can provide a better understanding of the air disinfection and airborne endotoxin removal processes.