Highly accelerated, real-time phase-contrast MRI using radial k-space sampling and GROG-GRASP reconstruction: a feasibility study in pediatric patients with congenital heart disease

利用径向k空间采样和GROG-GRASP重建技术实现高加速实时相位对比磁共振成像:一项针对先天性心脏病患儿的可行性研究

阅读:1

Abstract

Retrospective electrocardiogram-gated, 2D phase-contrast (PC) flow MRI is routinely used in clinical evaluation of valvular/vascular disease in pediatric patients with congenital heart disease (CHD). In patients not requiring general anesthesia, clinical standard PC is conducted with free breathing for several minutes per slice with averaging. In younger patients under general anesthesia, clinical standard PC is conducted with breath-holding. One approach to overcome this limitation is using either navigator gating or self-navigation of respiratory motion, at the expense of lengthening scan times. An alternative approach is using highly accelerated, free-breathing, real-time PC (rt-PC) MRI, which to date has not been evaluated in CHD patients. The purpose of this study was to develop a 38.4-fold accelerated 2D rt-PC pulse sequence using radial k-space sampling and compressed sensing with 1.5 × 1.5 × 6.0 mm(3) nominal spatial resolution and 40 ms nominal temporal resolution, and evaluate whether it is capable of accurately measuring flow in 17 pediatric patients (aortic valve, pulmonary valve, right and left pulmonary arteries) compared with clinical standard 2D PC (either breath-hold or free breathing). For clinical translation, we implemented an integrated reconstruction pipeline capable of producing DICOMs of the order of 2 min per time series (46 frames). In terms of association, forward volume, backward volume, regurgitant fraction, and peak velocity at peak systole measured with standard PC and rt-PC were strongly correlated (R(2) > 0.76; P < 0.001). Compared with clinical standard PC, in terms of agreement, forward volume (mean difference = 1.4% (3.0% of mean)) and regurgitant fraction (mean difference = -2.5%) were in good agreement, whereas backward volume (mean difference = -1.1 mL (28.2% of mean)) and peak-velocity at peak systole (mean difference = -21.3 cm/s (17.2% of mean)) were underestimated by rt-PC. This study demonstrates that the proposed rt-PC with the said spatial resolution and temporal resolution produces relatively accurate forward volumes and regurgitant fractions but underestimates backward volumes and peak velocities at peak systole in pediatric patients with CHD.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。