A GPU-accelerated framework for rapid estimation of scanner-specific scatter in CT for virtual imaging trials

一种用于虚拟成像试验的、利用GPU加速快速估计CT扫描仪特定散射的框架

阅读:2

Abstract

Virtual imaging trials (VITs), defined as the process of conducting clinical imaging trials using computer simulations, offer a time- and cost-effective alternative to traditional imaging trials for CT. The clinical potential of VITs hinges on the realism of simulations modeling the image acquisition process, where the accurate scanner-specific simulation of scatter in a time-feasible manner poses a particular challenge. To meet this need, this study proposes, develops, and validates a rapid scatter estimation framework, based on GPU-accelerated Monte Carlo (MC) simulations and denoising methods, for estimating scatter in single source, dual-source, and photon-counting CT. A CT simulator was developed to incorporate parametric models for an anti-scatter grid and a curved energy integrating detector with an energy-dependent response. The scatter estimates from the simulator were validated using physical measurements acquired on a clinical CT system using the standard single-blocker method. The MC simulator was further extended to incorporate a pre-validated model for a PCD and an additional source-detector pair to model cross scatter in dual-source configurations. To estimate scatter with desirable levels of statistical noise using a manageable computational load, two denoising methods using a (1) convolutional neural network and an (2) optimized Gaussian filter were further deployed. The viability of this framework for clinical VITs was assessed by integrating it with a scanner-specific ray-tracer program to simulate images for an image quality (Mercury) and an anthropomorphic phantom (XCAT). The simulated scatter-to-primary ratios agreed with physical measurements within 4.4% ± 10.8% across all projection angles and kVs. The differences of ∼121 HU between images with and without scatter, signifying the importance of scatter for simulating clinical images. The denoising methods preserved the magnitudes and trends observed in the reference scatter distributions, with an averaged rRMSE value of 0.91 and 0.97 for the two methods, respectively. The execution time of ∼30 s for simulating scatter in a single projection with a desirable level of statistical noise indicates a major improvement in performance, making our tool an eligible candidate for conducting extensive VITs spanning multiple patients and scan protocols.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。