Reproducibility of Aorta Segmentation on 4D Flow MRI in Healthy Volunteers

健康志愿者4D流速磁共振成像主动脉分割的可重复性

阅读:1

Abstract

BACKGROUND: Hemodynamic aorta parameters can be derived from 4D flow MRI, but this requires lumen segmentation. In both commercially available and research 4D flow MRI software tools, lumen segmentation is mostly (semi-)automatically performed and subsequently manually improved by an observer. Since the segmentation variability, together with 4D flow MRI data and image processing algorithms, will contribute to the reproducibility of patient-specific flow properties, the observer's lumen segmentation reproducibility and repeatability needs to be assessed. PURPOSE: To determine the interexamination, interobserver reproducibility, and intraobserver repeatability of aortic lumen segmentation on 4D flow MRI. STUDY TYPE: Prospective and retrospective. POPULATION: A healthy volunteer cohort of 10 subjects who underwent 4D flow MRI twice. Also, a clinical cohort of six subjects who underwent 4D flow MRI once. FIELD STRENGTH/SEQUENCE: 3T; time-resolved three-directional and 3D velocity-encoded sequence (4D flow MRI). ASSESSMENT: The thoracic aorta was segmented on the 4D flow MRI in five systolic phases. By positioning six planes perpendicular to a segmentation's centerline, the aorta was divided into five segments. The volume, surface area, centerline length, maximal diameter, and curvature radius were determined for each segment. STATISTICAL TESTS: To assess the reproducibility, the coefficient of variation (COV), Pearson correlation coefficient (r), and intraclass correlation coefficient (ICC) were calculated. RESULTS: The interexamination and interobserver reproducibility and intraobserver repeatability were comparable for each parameter. For both cohorts there was very good reproducibility and repeatability for volume, surface area, and centerline length (COV = 10-32%, r = 0.54-0.95 and ICC = 0.65-0.99), excellent reproducibility and repeatability for maximal diameter (COV = 3-11%, r = 0.94-0.99, ICC = 0.94-0.99), and good reproducibility and repeatability for curvature radius (COV = 25-62%, r = 0.73-0.95, ICC = 0.84-0.97). DATA CONCLUSION: This study demonstrated no major reproducibility and repeatability limitations for 4D flow MRI aortic lumen segmentation. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。