Backwashing performance of self-cleaning screen filters in drip irrigation systems

滴灌系统中自清洁筛网过滤器的反冲洗性能

阅读:1

Abstract

The self-cleaning screen filter is one of the most common types used in drip irrigation systems. Backwashing pressure difference and backwashing time for two screen filters with one geometry and two different screens (178 μm and 124 μm) using two water qualities (tap water and sand-water mixture) were studied in a total of 88 runs (42 runs for tap water, 22 and 24 filtration cycles for sand-water mixture and backwashing, respectively). The backwashing pressure difference and backwashing time were calculated using the experimental data, and the results were largely in the range of measured values. Three constraint conditions (flowrate, sand condition and filtration time) of backwashing pressure difference were analysed, and the optimal values of backwashing pressure difference were given as 60.0 and 70.0 kPa for 178 μm and 124 μm filters, respectively. The backwashing time of the screen filter should be an optimal value that ensures that the pressure difference between the internal and external surfaces of the screen decreased to the initial value, and the sand concentration of the backwashed outlet decreased to a small, stable value. Based on the results of the backwashing experiment and prototype observation, the optimal backwashing time was given as 30 to 45 s for both screen filters.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。