Detecting of the Longitudinal Grouting Quality in Prestressed Curved Tendon Duct Using Piezoceramic Transducers

利用压电陶瓷传感器检测预应力弯曲筋管纵向灌浆质量

阅读:1

Abstract

To understand the characteristics of longitudinal grouting quality, this paper developed a stress wave-based active sensing method using piezoceramic transducers to detect longitudinal grouting quality of the prestressed curved tendon ducts. There were four lead zirconate titanate (PZT) transducers installed in the same longitudinal plane. One of them, mounted on the bottom of the curved tendon duct, was called as an actuator for generating stress waves. The other three, pasted on the top of the curved tendon duct, were called as sensors for detecting the wave responses. The experimental process was divided into five states during the grouting, which included 0%, 50%, 75%, 90%, and 100% grouting. The voltage signals, power spectral density (PSD) energy and wavelet packet energy were adopted in this research. Experimental results showed that all the amplitudes of the above analysis indicators were small before the grouting reached 90%. Only when the grouting degree reached the 100% grouting, these parameters increased significantly. The results of different longitudinal PZT sensors were mainly determined by the distance from the generator, the position of grouting holes, and the fluidity of grouting materials. These results showed the longitudinal grouting quality can be effectively evaluated by analyzing the difference between the signals received by the PZT transducers in the curved tendon duct. The devised method has certain application value in detecting the longitudinal grouting quality of prestressed curved tendon duct.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。