Preliminary experience with continuous right ventricular pressure and transesophageal echocardiography monitoring in orthotopic liver transplantation

原位肝移植中连续右心室压力和经食道超声心动图监测的初步经验

阅读:2

Abstract

BACKGROUND: Despite increasing attention in the cardiac anesthesiology literature, continuous measurement of right ventricular pressure using a pulmonary artery catheter has not been described in orthotopic liver transplantation, despite similarities in the anesthetic approach to the two populations. We describe our preliminary experience with this technique in orthotopic liver transplantation, and by combining various derived measures with trans-esophageal echocardiography, make some early observations regarding the response of these measures of right ventricular function during the procedure. METHODS: In this case series, ten patients (five men and five women) undergoing orthotopic liver transplantation in our institution had their surgeries performed while monitored with a pulmonary artery catheter with continuous right ventricular port transduction and trans-esophageal echocardiography. We recorded various right ventricular waveform (early-to-end diastolic pressure difference, right ventricular outflow tract gradient, right ventricular dP/dT and right ventricular end-diastolic pressure) and echocardiographic (right ventricular fractional area change, tricuspid annular plane systolic excursion, right ventricular lateral wall strain) and described their change relative to baseline at timepoints five minutes before and after portal vein reperfusion, immediately after hepatic artery reperfusion and on abdominal closure. RESULTS: Except for tricuspid annular plane systolic excursion at five minutes prior to reperfusion (mean -0.8 cm; 95% CI-1.4, -0.3; p = 0.007), no echocardiographic metric was statistically significantly different at any timepoint relative to baseline. In contrast, changes in right ventricular outflow tract gradient and right ventricular dP/dt were highly significant at multiple timepoints, generally peaking immediately before or after reperfusion before reducing, but not returning to baseline in the neohepatic phase. Nine of 10 participants in this series demonstrated a degree of dynamic right ventricular outflow tract obstruction, which met criteria for hemodynamic significance (> 25 mmHg) in two participants. These changes were not materially affected by cardiac index. CONCLUSIONS: Dynamic right ventricular outflow tract obstruction of varying severity appears common in patients undergoing orthotopic liver transplantation. These results are hypothesis generating and will form the basis of future prospective research.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。