Abstract

A rapid, accurate, and selective analytical method to simultaneously quantify 13 anticoagulant rodenticides in animal biological samples was developed using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) coupled with electrospray ionization (ESI) in negative mode. Samples were extracted and purified based on a modified QuEChERS (quick, easy, cheap, effective, rugged, safe) sample preparation technique. The sample pH and the type of extraction solvent and cleanup sorbent used to estimate the procedure's effectiveness were optimized. To improve the matrix effects and obtain acceptable recoveries for 13 rodenticides, 0.1 mL/g biological sample and 1 mL acetonitrile (or acetonitrile: EtOAc = 1:1/(v:v)) extraction followed by Florisil/HC-C18/anhydrous Na2SO4 (NaCl) cleanup under alkaline conditions was fully validated and shown to be selective, precise, accurate, and linear in the range from 1 to 100 ng/mL (g). The mean recoveries were between 52.78 and 110.69%, while the limits of detection and quantification ranged from 0.05 to 0.5 and 0.1-1 ng/mL (μg/kg), respectively. Ideal soft matrix effects (≤20%) were observed for the vast majority of rodenticides (>95%) showing either suppression or enhancement. This method meets international criteria and is capable of simultaneously identifying and quantifying anticoagulant rodenticides in animal blood and tissues and can be suitable for the detection of poisoning cases in the field of forensic or public health.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。