A paradigm shift in oncology imaging: a prospective cross-sectional study to assess low-dose deep learning image reconstruction versus standard-dose iterative reconstruction for comprehensive lesion detection in dual-energy computed tomography

肿瘤成像领域的范式转变:一项前瞻性横断面研究,旨在评估低剂量深度学习图像重建与标准剂量迭代重建在双能计算机断层扫描中全面检测病灶方面的差异

阅读:1

Abstract

BACKGROUND: Low-kiloelectron volt (keV) virtual monochromatic images (VMIs) from low-dose (LD) dual-energy computed tomography (DECT) can enhance lesion contrast but suffer from high image noise. Recently, a deep learning image reconstruction (DLIR) algorithm has been developed and shown significant potential in suppressing image noise and improving image quality. To date, the capacity of LD low-keV thoracic-abdominal-pelvic DECT with DLIR to detect various types of tumor lesions have not been assessed. Hence, this study aimed to evaluate the image quality and lesion detection capabilities of LD VMIs using DLIR with thoracic-abdominal-pelvic DECT versus standard-dose (SD) iterative reconstruction (IR) in oncology patients. METHODS: This prospective intraindividual study included 56 oncology patients who received a SD (13.86 mGy) and a consecutive LD (7.15 mGy) thoracic-abdominal-pelvic DECT from April 2022 to July 2023 at The First Affiliated hospital of Zhengzhou University. SD VMIs were reconstructed using IR at 50 keV (SD-IR(50 keV)), while LD VMIs were processed using DLIR at 50 keV (LD-DL(50 keV)) and 40 keV (LD-DL(40 keV)), respectively. Quantitative image parameters [computed tomography (CT) values, image noise, and contrast-to-noise ratios (CNRs)], qualitative metrics (image noise, vessel conspicuity, image contrast, artificial sensation, and overall image quality), and lesion CNRs and conspicuity were compared. The lesion detection rates in the SD-IR(50 keV), LD-DL(50 keV), and LD-DL(40 keV) VMIs were assessed according to lesion location (lung, liver, and lymph), type, and size. Repeated measures analysis of variance and the Friedman test were applied for comparing quantitative and qualitative measures, respectively. The Cochran Q test was used for comparing lesion detection rates. RESULTS: Compared to SD-IR(50 keV) VMIs, LD-DL(50 keV) VMIs showed similar CT values and image noise (P>0.05), similar (P>0.05) or higher(P<0.05) CNRs, similar (P>0.05) or superior (P<0.05) perceptual image quality, and similar (P>0.05) or higher (P<0.001) lesion CNR and conspicuity. LD-DL(40 keV) VMIs exhibited higher CT values (by 40.4-47.1%) and CNRs (by 21.8-39.8%) (P<0.001), equivalent image noise, similar (P>0.05) or superior (P<0.05) perceptual image quality except for artificial sensation, and similar (P>0.05) or higher (P<0.001) lesion CNRs (by 16.5-46.3%) and conspicuity. The VMIs of LD-DL(50 keV) and LD-DL(40 keV) were consistent with those of SD-IR(50 keV) in terms of lesion detection capability in pulmonary nodules [SD-IR(50 keV) vs. LD-DL(50 keV) vs. LD-DL(40 keV): 88/88 (100.0%) vs. 88/88 (100.0%) vs. 88/88 (100.0%); P>0.99], for lymph nodes [125/126 (99.2%) vs. 123/126 (97.6%) vs. 124/126 (98.4%); P>0.05], and high-contrast liver lesions [12/12 (100.0%) vs. 12/12 (100.0%) vs. 12/12 (100.0%); P>0.05], but not for small liver lesions (≤0.5 cm) [63/65 (96.9%) vs. 43/65 (66.2%) vs. 51/65 (78.5%); P<0.05] or low-contrast liver lesions [198/200 (99.0%) vs. 174/200 (87.0%) vs. 183/200 (91.5%); P<0.05]. CONCLUSIONS: VMIs at 40 keV with DLIR enables a 50% decrease in the radiation dose while largely maintaining diagnostic capabilities for multidetection of pulmonary nodules, lymph nodes, and liver lesions in oncology patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。