Ultrasensitive Electrical Detection of Hemagglutinin for Point-of-Care Detection of Influenza Virus Based on a CMP-NANA Probe and Top-Down Processed Silicon Nanowire Field-Effect Transistors

基于CMP-NANA探针和自上而下加工的硅纳米线场效应晶体管的超灵敏血凝素电学检测用于流感病毒即时检测

阅读:1

Abstract

Rather than the internal genome nucleic acids, the biomolecules on the surface of the influenza virus itself should be detected for a more exact and rapid point-of-care yes/no decision for influenza virus-induced infectious diseases. This work demonstrates the ultrasensitive electrical detection of the HA1 domain of hemagglutinin (HA), a representative viral surface protein of the influenza virus, using the top-down complementary metal oxide semiconductor (CMOS) processed silicon nanowire (SiNW) field-effect transistor (FET) configuration. Cytidine-5'-monophospho-N-acetylneuraminic acid (CMP-NANA) was employed as a probe that specifically binds both to the aldehyde self-aligned monolayer on the SiNWs and to HA1 simultaneously. CMP-NANA was serially combined with two kinds of linkers, namely 3-aminopropyltriethoxysilane and glutaraldehyde. The surface functionalization used was verified using the purification of glutathione S-transferase-tagged HA1, contact angle measurement, enzyme-linked immunosorbent assay test, and isoelectric focusing analysis. The proposed functionalized SiNW FET showed high sensitivities of the threshold voltage shift (ΔV(T)) ~51 mV/pH and the ΔV(T) = 112 mV (63 mV/decade) with an ultralow detectable range of 1 fM of target protein HA1.