Sunday 26 March 2017

2017年3月26日,星期日

阅读:1

Abstract

INTRODUCTION: The purpose of this study was to evaluate the dosimetric and radiobiological impact of intensity modulated proton therapy (IMPT) and RapidArc planning for high-risk prostate cancer with seminal vesicles. METHODS: Ten high-risk prostate cancer cases were included in this retrospective study. For each case, IMPT plans were generated using multiple field optimisation (MFO) technique (two fields) with XiO treatment planning system (TPS), whereas RapidArc plans were generated using double-arc technique (two full arcs) with Eclipse TPS. IMPT and RapidArc plans were optimised for a total prescription dose of 79.2 Gy (relative biological effectiveness (RBE)) and 79.2 Gy, respectively, using identical dose-volume constraints. IMPT and RapidArc plans were then normalised such that at least 95% of the planning target volume (PTV) received the prescription dose. RESULTS: The mean and maximum PTV doses were comparable in IMPT plans (80.1 ± 0.3 Gy (RBE) and 82.6 ± 1.0 Gy (RBE) respectively) and RapidArc plans (80.3 ± 0.3 Gy and 82.8 ± 0.6 Gy respectively) with P = 0.088 and P = 0.499 respectively. The mean doses of the rectum and bladder were found to be significantly lower in IMPT plans (16.9 ± 5.8 Gy (RBE) and 17.5 ± 5.4 Gy (RBE) respectively) when compared to RapidArc plans (41.9 ± 5.7 Gy and 32.5 ± 7.8 Gy respectively) with P < 0.000 and P < 0.000 respectively. For the rectum, IMPT produced lower V(30) (21.0 ± 9.6% vs. 68.5 ± 10.0%; P < 0.000), V(50) (14.3 ± 5.8% vs. 45.0 ± 10.0%; P < 0.000) and V(70) (6.9 ± 3.4% vs. 12.8 ± 3.6%; P < 0.000) compared to RapidArc. For the bladder, IMPT produced lower V(30) (23.2 ± 7.0% vs. 50.9 ± 15.6%; P < 0.000) and V(50) (16.6 ± 5.4% vs. 25.1 ± 9.6%; P = 0.001), but similar V(70) (9.7 ± 3.5% vs. 10.5 ± 4.2%; P = 0.111) compared to RapidArc. RapidArc produced lower mean dose for both the right femoral head (19.5 ± 4.2 Gy vs. 27.4 ± 4.5 Gy (RBE); P < 0.000) and left femoral head (18.0 ± 4.3 Gy vs. 28.0 ± 5.6 Gy (RBE); P < 0.000). Both IMPT and RapidArc produced comparable bladder normal tissue complication probability (NTCP) (0.6 ± 0.2% vs. 0.5 ± 0.2%; P = 0.152). The rectal NTCP was found to be lower using IMPT (0.8 ± 0.7%) than using RapidArc (1.7 ± 0.7%) with P < 0.000. CONCLUSION: Both IMPT and RapidArc techniques provided comparable mean and maximum PTV doses. For the rectum, IMPT produced better dosimetric results in the low-, medium- and high-dose regions and lower NTCP compared to RapidArc. For the bladder, the NTCP and dosimetric results in the high-dose region were comparable in both sets of plans, whereas IMPT produced better dosimetric results in the low- and medium-dose regions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。