Unexpected iatrogenic fracture of the femoral neck during subtrochanteric fracture fixation in a patient on bisphosphonate treatment for osteoporosis: Case report

骨质疏松症患者接受双膦酸盐治疗期间,在股骨粗隆下骨折内固定术中意外发生医源性股骨颈骨折:病例报告

阅读:2

Abstract

Osteoporotic patients being treated with bisphosphonates present an interesting dilemma when removing hardware such as dynamic hip screws "DHS". In this paper, we describe the case of a 66-year-old osteoporotic patient who was placed on long term bisphosphonate therapy after sustaining an intertrochanteric hip fracture which was stabilized with a DHS. She presented with a subtrochantric fracture on the ipsilateral side. She was planned for DHS removal and intramedullary nailing. Removal of the dynamic hip screw proved to be difficult, likely due to possible cold welding of the DHS to the barrel of the side plate and sclerotic bone formation around the hardware secondary to the extended bisphosphonate use. The patient had an intra-operative femoral neck fracture while attempting the DHS removal. We had to convert to an unanticipated total hip replacement. Careful considerations should be taken when removing hardware from patients on long term bisphosphonate treatment.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。