Non-Invasive Wide-Field Imaging of Chip Surface Temperature Distribution Based on Ensemble Diamond Nitrogen-Vacancy Centers

基于金刚石氮空位中心集合的非侵入式芯片表面温度分布宽场成像

阅读:1

Abstract

With the development of chip technology, the demand for device reliability in various electronic chip industries continues to grow. In recent years, with the advancement of quantum sensors, the solid-state spin (nitrogen-vacancy) NV center temperature measurement system has garnered attention due to its high sensitivity and spatial range. However, NV centers are not only affected by temperature but also by magnetic fields. This article analyzes the impact of magnetic fields on temperature detection. By combining the wide-field imaging platform of optically detected magnetic resonance (ODMR) with a temperature-sensitive structure of thin ensemble diamond overlaid on a quartz substrate, high-sensitivity temperature detection has been achieved. And obtains a sensitivity of approximately 10 mK/Hz(1/2). By combining a CCD camera imaging system, it realizes a wide field of view of 500 μm(2), a high spatial resolution of 1.3 μm. Ultimately, this study demonstrates the two-dimensional actual temperature distribution on the chip surface under different currents, achieving wide-field, non-contact, high-speed temperature imaging of the chip surface.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。