Feasibility study of automatic radiotherapy treatment planning for cervical cancer using a large language model

基于大型语言模型的宫颈癌自动放射治疗计划可行性研究

阅读:1

Abstract

BACKGROUND: Radiotherapy treatment planning traditionally involves complex and time-consuming processes, often relying on trial-and-error methods. The emergence of artificial intelligence, particularly Large Language Models (LLMs), surpassing human capabilities and existing algorithms in various domains, presents an opportunity to automate and enhance this optimization process. PURPOSE: This study seeks to evaluate the capacity of LLMs to generate radiotherapy treatment plans comparable to those crafted by human medical physicists, focusing on target volume conformity and organs-at-risk (OARs) dose sparing. The goal is to automate the optimization process of radiotherapy treatment plans through the utilization of LLMs. METHODS: Multiple LLMs were employed to adjust optimization parameters for radiotherapy treatment plans, using a dataset comprising 35 cervical cancer patients treated with volumetric modulated arc therapy (VMAT). Customized prompts were applied to 5 patients to tailor the LLMs, which were subsequently tested on 30 patients. Evaluation metrics included target volume conformity, dose homogeneity, monitor units (MU) value, and OARs dose sparing, comparing plans generated by various LLMs to manual plans. RESULTS: With the exception of Gemini-1.5-flash, which faced challenges due to hallucinations, Qwen-2.5-max and Llama-3.2 produced acceptable VMAT plans in 16.3 ± 5.0 and 9.8 ± 2.1 min, respectively, outperforming an experienced human physicist's time cost of about 20 min. The average conformity index (CI) for Qwen-2.5-max plans, Llama-3.2 plans, and manual plans on the test set were 0.929 ± 0.007, 0.928 ± 0.007, and 0.926 ± 0.007, respectively. The average homogeneity index (HI) was 0.058 ± 0.006, 0.059 ± 0.005, and 0.065 ± 0.006, respectively. While there was a significant difference in target volume conformity between LLM plans and manual plans, OARs dose sparing showed no significant variations. In lateral comparisons among different LLMs, no statistically significant differences were observed in the PTV dose, OARs dose sparing, and target volume conformity between Qwen-2.5-max and Llama-3.2 plans. CONCLUSIONS: Through an assessment of LLM-generated plans and clinical plans in terms of target volume conformity and OARs dose sparing, this study provides preliminary evidence supporting the viability of LLMs for optimizing radiotherapy treatment plans. The implementation of LLMs demonstrates the potential for enhancing clinical workflows and reducing the workload associated with treatment planning.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。