Reliability and responsiveness of a tissue hardness meter and algometer for measuring tissue hardness and pressure pain threshold in upper trapezius myofascial trigger points

组织硬度计和测痛仪在测量上斜方肌肌筋膜触发点的组织硬度和压力痛阈值方面的可靠性和响应性

阅读:1

Abstract

BACKGROUND: Tissue hardness meter and algometer (THA) are used to assess tissue hardness (TH) and pressure pain threshold (PPT), particularly in the evaluation of myofascial trigger points (MTrPs). This study introduces a side-lying protocol designed to comprehensively measure all portions of the upper trapezius (UT) muscle. PURPOSE: The objective was to determine the reliability and responsiveness of THA to measure TH and PPT in patients with MTrPs in the UT muscle. METHODS: Reliability of TH and PPT measurements was assessed in a sample of 24 participants. Intra-rater and inter-rater reliability were evaluated using the intra-class correlation coefficient (ICC(3,1)), while absolute reliability was established via Bland-Altman analysis, including the calculation of 95% limits of agreement (95% LoA). To assess responsiveness, 36 additional participants were recruited. Both distribution-based methods (mean difference, effect size (ES), standardized response mean (SRM), standard error of measurement (SEM), and minimal detectable change at 95% confidence (MDC(95))) and anchor-based methods (minimal clinically important difference (MCID) and area under the curve (AUC)) were utilized in the analysis. RESULTS: Intra-rater reliability was excellent for both TH and PPT (ICC(3,1): 0.95-0.97), while inter-rater reliability was moderate (ICC(3,1): 0.60). Evidence of both fixed and proportional bias was identified for both TH and PPT. For TH, the SEM and MDC(95) were 2.66% and 7.37%, respectively, while for PPT, they were 0.12 kg/cm(2) and 0.34 kg/cm(2), respectively. Following six physical therapy sessions, significant reductions in TH (mean: -7.86%; MCID: -7.43%; AUC: 0.97) and significant increases in PPT (mean: 0.20 kg/cm(2); MCID: 0.21 kg/cm(2); AUC: 0.86) were observed. Additionally, changes in PPT showed a negative correlation with improvements in the Neck Disability Index (NDI) (r = -0.35, p < 0.05). CONCLUSION: The side-lying protocol demonstrated reliable and clinically relevant TH and PPT measurements, supporting its use for monitoring treatment outcomes in patients with MTrPs in the UT muscle.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。