Time and Frequency Domain Analysis of IMU-Based Orientation Estimation Algorithms with Comparison to Robotic Arm Orientation as Reference

基于IMU的姿态估计算法的时域和频域分析,并以机械臂姿态作为参考进行比较

阅读:1

Abstract

This work focuses on time and frequency domain analyses of IMU-based orientation estimation algorithms, including indirect Kalman (IKF), Madgwick (MF), and complementary (CF) filters. Euler angles and quaternions are used for orientation representation. A 6-DoF IMU is attached to a 6-joint UR5e robotic arm, with the robot's orientation serving as the reference. Robotic arm data is obtained via an RTDE interface and IMU data via a CAN bus. Test signals include pose sequences, which are big-amplitude, slowly changing signals used to evaluate stationary and low-dynamics responses in the time domain, and small-amplitude, fast-changing generalized binary noise (GBN) signals used to evaluate dynamic responses in the frequency domain. To prevent poor filters' performance, their parameters are tuned. In the time domain, RMSE and MaxAE are calculated for roll and pitch. In the frequency domain, composite frequency response and coherence are calculated using the Ockier method. RMSEs are computed for response magnitude and coherence, and averaged equivalent time delay (AETD) is derived from the response phase. In the time domain, MF and CF show the best overall performance. In the frequency domain, they again perform similarly well. IKF consistently performs the worst in both domains but achieves the lowest AETD.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。