Enhancing needle puncture detection using high-pass filtering and diffuse reflectance

利用高通滤波和漫反射增强针刺检测

阅读:1

Abstract

INTRODUCTION: Chest trauma or disease progression can lead to tension pneumothorax, a condition where mounting pressurization of the pleural cavity (the space between the chest wall and the lungs) leads rapidly to cardiac arrest. In pre-hospital settings, tension pneumothorax is treated by venting the pleural cavity via a needle introduced through the chest wall. Very high failure rates (up to 94.1%) have been reported for pre-hospital needle decompression, however, and the procedure can result in the accidental puncture of critical thoracic tissues because it is performed blind. Instrumented needles could help operators more reliably identify when the tool has entered the target space. METHODS: This paper investigates technical approaches to provide such support; we created an experimental system that acquires needle force and position signals, as well as the diffuse backscattered reflectance from white light carried to and collected from the needle's tip via two in-bore optical fibers. Data collection occurred while two experimenters inserted a bevel-tipped percutaneous needle into an ex vivo porcine rib section simulating human chest anatomy. Four data-driven puncture-detection (DDPD) algorithms from the literature, which are appropriate for use with the variable tool velocities produced by manual insertions, were applied to the resulting data set offline. Grid search was performed across key signal-processing parameters, high-pass filters (HPFs) were applied to examine their impact on puncture detection, and a first exploration of multimodal (ensemble) methods was performed. RESULTS: Combining high-pass filters with DDPD methods resulted in a 2.7-fold improvement (from 8.2% to 21.9%) in the maximum overall precision (MOP) produced by force signals. Applying this HPF + DDPD scheme to reflectance data streams yielded a peak MOP of 36.4%, and combining reflectance with force generated the best MOP overall (42.1%); these results represent 4.4-fold and 5.1-fold improvements, respectively, over the best MOP produced by the traditional application of DDPD algorithms to force signals alone. DISCUSSION: These results strongly support the utility of high-pass filters combined with both reflectance-only and multimodal reflectance-plus-force data-driven puncture-detection schemes for needle decompression applications.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。