Estimating the optical properties of corneal tissue from the OCT speckle

利用OCT散斑估算角膜组织的光学特性

阅读:1

Abstract

Estimating the scattering coefficient μ (s) and scattering anisotropy factor g of the corneal tissue is currently limited to methods utilizing double integrating spheres or spectroscopic techniques, prohibiting such corneal tissue evaluation from being performed in a clinical setting. This paper presents a new concept of statistical matching between a given corneal optical coherence tomography (OCT) scan and a set of multi-reference phantom OCT B-scans, suitably simulated using the Monte Carlo method. The statistical matching that exploits the information present in the speckle includes an ensemble of distance measures. Using a set of OCT scans from 11 porcine eyeballs, for which epithelium was removed, it is demonstrated that the proposed statistical matching approach leads to a precise estimation of the optical properties of corneal stroma. The group mean of the scattering coefficient and the scattering anisotropy factor for the porcine stroma were μ¯s = 0.146 ± 0.020 mm(-1) and g¯ = 0.893 ± 0.021 , respectively. These estimates match previously reported values established with other methods. The proposed approach of utilizing information present in the speckle can be readily extended to in vivo OCT imaging of human corneal tissue.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。