Opportunistic assessment of osteoporosis using hip and pelvic X-rays with OsteoSight™: validation of an AI-based tool in a US population

利用 OsteoSight™ 对髋部和骨盆 X 光片进行骨质疏松症的机会性评估:基于人工智能的工具在美国人群中的验证

阅读:1

Abstract

Identifying patients at risk of low bone mineral density (BMD) from X-rays presents an attractive approach to increase case finding. This paper showed the diagnostic accuracy, reproducibility, and robustness of a new technology: OsteoSight™. OsteoSight could increase diagnosis and preventive treatment rates for patients with low BMD. PURPOSE: This study aimed to evaluate the diagnostic accuracy, reproducibility, and robustness of OsteoSight™, an automated image analysis tool designed to identify low bone mineral density (BMD) from routine hip and pelvic X-rays. Given the global rise in osteoporosis-related fractures and the limitations of current diagnostic paradigms, OsteoSight offers a scalable solution that integrates into existing clinical workflows. METHODS: Performance of the technology was tested across three key areas: (1) diagnostic accuracy in identifying low BMD as compared to dual-energy X-ray absorptiometry (DXA), the clinical gold standard; (2) reproducibility, through analysis of two images from the same patient; and (3) robustness, by evaluating the tool's performance across different patient demographics and X-ray scanner hardware. RESULTS: The diagnostic accuracy of OsteoSight for identifying patients at risk of low BMD was area under the receiver operating characteristic curve (AUROC) 0.834 [0.789-0.880], with consistent results across subgroups of clinical confounders and X-ray scanner hardware. Specificity 0.852 [0.783-0.930] and sensitivity 0.628 [0.538-0.743] met pre-specified acceptance criteria. The pre-processing pipeline successfully excluded unsuitable cases including incorrect body parts, metalwork, and unacceptable femur positioning. CONCLUSION: The results demonstrate that OsteoSight is accurate in identifying patients with low BMD. This suggests its utility as an opportunistic assessment tool, especially in settings where DXA accessibility is limited or not recently performed. The tool's reproducibility and robust performance across various clinical confounders further supports its integration into routine orthopedic and medical practices, potentially broadening the reach of osteoporosis assessment and enabling earlier intervention for at-risk patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。