A loop-mediated isothermal amplification assay for the detection and quantification of JC polyomavirus in cerebrospinal fluid: a diagnostic and clinical management tool and technique for progressive multifocal leukoencephalopathy

一种用于检测和定量脑脊液中JC多瘤病毒的环介导等温扩增检测方法:一种用于进行性多灶性白质脑病的诊断和临床管理工具及技术

阅读:1

Abstract

BACKGROUND: JC polyomavirus (JCV) is the causative agent of progressive multifocal leukoencephalopathy (PML), a demyelinating disease of the central nervous system in immunosuppressed patients. PML usually has a poor prognosis. Detection and quantification of the JCV genome in cerebrospinal fluid (CSF) is an efficacious tool for the diagnosis and management of PML, for which proper therapeutic interventions are required. METHODS: A loop-mediated isothermal amplification (LAMP) assay was applied for the quantitative detection of JCV. The LAMP assay was evaluated for the efficacy in diagnosis of PML in comparison with the TaqMan-based quantitative real-time PCR (qPCR) assay using 153 CSF specimens collected from patients with suspected PML. RESULTS: The LAMP assay showed no cross-reactivity against other polyomavirus plasmids, viral DNA, and viral RNA, which causes encephalitis, and detected 1 copy of the standard DNA per reaction. Among 50 qPCR-positives, 42 specimens (containing JCV genome ranged from 3.2 × 10(0) to 3.2 × 10(6) copies/reaction) showed positive reactions and 8 specimens (containing 0.9 to 19.9 copies/reaction) showed negative in the LAMP assay. Furthermore, 3 of 103 qPCR-negative specimens showed positive reactions in the LAMP assay. The sensitivity, specificity, positive predictive value, and negative predictive values of the LAMP assay were 84% (42/50), 97% (100/103), 93% (42/45), and 93% (100/108), respectively. The kappa statistic was 0.83. The JCV loads determined by the LAMP assay showed a strong positive correlation with those determined by the qPCR assay for 33 specimens with copy numbers of ≥1 copies/reaction (r = 0.89). Additionally, the LAMP assay could monitor the JCV genome copy number in CSF for sequential samples equivalently to qPCR assay. CONCLUSIONS: The newly developed LAMP assay is highly specific against JCV and detect the JCV genome in the sample DNA containing 20 or more copies of JCV genome per reaction with 100% sensitivity (n = 29), which corresponds to ≥3 × 10(3) copies/mL of CSF. The LAMP assay is useful for the diagnosis and offers valuable information for the evaluation and management of PML in the clinical setting.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。