Application of a novel in vivo imaging approach to measure pulmonary vascular responses in mice

应用一种新型体内成像方法测量小鼠肺血管反应

阅读:1

Abstract

Noninvasive imaging of the murine pulmonary vasculature is challenging due to the small size of the animal, limits of resolution of the imaging technology, terminal nature of the procedure, or the need for intravenous contrast. We report the application of laboratory-based high-speed, high-resolution x-ray imaging, and image analysis to detect quantitative changes in the pulmonary vascular tree over time in the same animal without the need for intravenous contrast. Using this approach, we detected an increased number of vessels in the pulmonary vascular tree of animals after 30 min of recovery from a brief exposure to inspired gas with 10% oxygen plus 5% carbon dioxide (mean ± standard deviation: 2193 ± 382 at baseline vs. 6177 ± 1171 at 30 min of recovery; P < 0.0001). In a separate set of animals, we showed that the total pulmonary blood volume increased (P = 0.0412) while median vascular diameter decreased from 0.20 mm (IQR: 0.15-0.28 mm) to 0.18 mm (IQR: 0.14-0.26 mm; P = 0.0436) over the respiratory cycle from end-expiration to end-inspiration. These findings suggest that the noninvasive, nonintravenous contrast imaging approach reported here can detect dynamic responses of the murine pulmonary vasculature and may be a useful tool in studying these responses in models of disease.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。