Implications of phase difference and amplitude ratio from intracochlear and extracochlear electrocochleography in normal-hearing guinea pigs

正常听力豚鼠耳蜗内和耳蜗外电耳蜗图相位差和振幅比的意义

阅读:1

Abstract

INTRODUCTION: Electrocochleography (ECochG) can be performed extracochlearly from the round window, as well as intracochlearly from an electrode array as used in cochlear implantation. Cochlear microphonic (CM) amplitude ratio and phase difference from two fixed intracochlear electrodes may improve insight into local cochlear trauma after cochlear implantation. METHODS: Six normal-hearing guinea pigs underwent cochleostomy and cochlear implantation. ECochG was recorded in response to pure tones between 0.25 and 16 kHz from one extracochlear site El_Ex and two intracochlear sites: El_Ap and El_Bs. The CM was analyzed in terms of threshold, amplitude ratio and phase difference. Regarding the analyses of the latter we focused on CM at 2 and 4 kHz. The compound action potential (CAP) was analyzed in terms of threshold and amplitude. Histological trauma and hair cell counts were determined in midmodiolar sections. RESULTS: Both CM and CAP thresholds from El_Ap were approximately 5-10 dB lower than from El_Bs (CM thresholds: p = 0.003, CAP thresholds: p = 0.03). Across frequencies 0.25-8 kHz, CM amplitudes from El_Ap were a factor 4-8 larger than amplitudes from El_Ex (p < 0.001) and a factor 2-4 larger than amplitudes from El_Bs (p < 0.001). Across frequencies 0.25-8 kHz CAP amplitudes from El_Ap were a factor 2 larger than amplitudes from El_Bs (p = 0.02). The CM amplitude ratios between both intracochlear electrodes varied among animals from 1.7 to above 10 (median amplitude ratio: 2 kHz = 6.86; 4 kHz = 3.56), and CM phase differences varied from near 0 to -π (median phase difference: 2 kHz = -0.13π; 4 kHz = -0.32π). Four different combinations of small or large CM phase difference and small or large CM amplitude ratio were identified. In all animals, hair cell counts were normal. Histological trauma in the lateral wall around the site of cochleostomy was mild in four animals and moderate in two animals. DISCUSSION: In addition to conventional electrophysiological thresholds, combinations of small or large CM phase difference and amplitude ratio from two intracochlear electrodes may mirror specific patterns of cochlear trauma as caused by cochlear implantation surgery.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。