Effect of contrast material injection duration on arterial enhancement at CT in patients with various cardiac indices: Analysis using computer simulation

对比剂注射时间对不同心脏指数患者CT动脉期增强的影响:计算机模拟分析

阅读:1

Abstract

Arterial peak enhancement on contrast-enhanced CT (CECT) images is thought to be higher in patients with low cardiac function. Using computer simulations, we tested the hypothesis that the relationship between the cardiac index and the aortic peak CT number (PCTN) is affected by the contrast material (CM) injection duration. We created computer simulation software for the contrast enhancement of various organs and vessels based on the Bae pharmacokinetics model and implemented models for CM transmission within organs and CM diffusion in blood plasma based on the osmotic pressure. Aortic contrast enhancement at coronary- and abdominal CT angiographs (CTA) was simulated for a representative 60-year-old Japanese male 166 cm in height and 65.0 kg in weight. The injection protocol for coronary CTA was: CM dose 45.5 ml, iodine dose, 245 mg/kg body weight (BW); injection duration 8-20 sec in 2-sec increments. For abdominal CTA it was CM dose 74.3 ml; iodine dose 400 mg/kg BW; injection duration 10-40 sec in 5-sec increments. In both protocols the iodine concentration was 350 mgI/ml, osmotic pressure was 590 mOsm/kgH2O, and the cardiac index ranged from 0.1-6.0 l/min/m2. Under all protocols, the aortic PCTN increased as the injection duration decreased and as the cardiac index rose to the cardiac index value. It then decreased as it exceeded the cardiac index value. At coronary CTA, at an injection duration of 8 or 10 sec, the PCTN exceeded 350 Hounsfield units (HU) at a cardiac index from 0.9-5.6 l/min/m2. At an HU value greater than 350, the range of the cardiac index narrowed when the injection duration was 12 sec or longer. On abdominal CTA scans performed with an injection duration of 10-, 15-, or 20 sec, the PCTN exceeded 350 HU at a cardiac index ranging from 0.4-5.3 l/min/m2. When the injection duration ranged from 25-40 sec, there was narrowing of the range of the cardiac index at which the PCTN exceeded 350 HU. For coronary and abdominal CTA, contrast enhancement protocols with shorter injection durations yield a diagnostically adequate aortic PCTN at a wide range of cardiac indices.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。