Poor condyle position after mandibular reconstruction and a classification system for patients with "VSCU" based on computed tomography: a cross-sectional study with retrospective data collection

下颌重建术后髁突位置不良及基于计算机断层扫描的“VSCU”患者分类系统:一项回顾性数据收集的横断面研究

阅读:1

Abstract

BACKGROUND: Although the application of vascularized free bone muscle flap to reconstruct the mandible has become a standardized approach for mandible reconstruction, the results of its reconstruction are not always satisfactory. The purpose of this study was to identify the types of mandibular and condylar defects by analyzing the unsatisfactory cases of mandibular reconstruction in clinical practice, and to provide some clinical experience of reconstruction. METHODS: Our study retrospectively analyzed 364 patients who underwent mandibular resection and vascularized free bone flap reconstruction of the mandible and temporomandibular joint (TMJ). We innovatively proposed a "VSCU" classification system (V: vertical position, S: sagittal position, C: coronal position, U: condylar resection is not required) by analyzing computed tomography (CT) scans of mandibular branches and TMJs. RESULTS: In all, 221 cases of free iliac muscle flap and 143 cases of fibula muscle flap were included in this study, of which 23 cases had unsatisfactory results after TMJ reconstruction. We classified 23 patients with unsatisfactory mandibular reconstruction according to the "VSCU" classification system. The most common type was U + V + SfC (n=8), followed by V - SfC + U + (n=4), V - s + C + U + (n=3), V - sbcou - (n=3), V - SBC + U + (n=2), V - s + C + U - (n=1). The most common classification was insufficient mandibular rami length, followed by condylar sagittal anteriorization. There was no significant change in the position of condyle on the healthy side during mandibular reconstruction involving condyle. P1 on the affected side was 52.28±4.17 mm before operation and 58.94±5.65 mm after operation, P<0.01; P2 was 12.83±3.49 mm before operation and 24.90±7.15 mm after operation. S2 was 4.54±2.84 mm before operation and 19.10±8.54 mm after operation. A2 was 11.46±3.35 mm before operation and 24.15±8.29 mm after operation. The P values were all less than 0.01, and the differences were statistically significant. CONCLUSIONS: We propose to use the "VSCU" classification system for accurate 3-dimensional (3D) analysis and positioning, and then obtain accurate models through computer-aided design and manufacturing (CAD/CAM), which can reduce the occurrence of poor reconstruction effect and unreasonable joint position, and is worthy of clinical promotion.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。