Fully automated deep learning system for osteoporosis screening using chest computed tomography images

利用胸部计算机断层扫描图像进行骨质疏松症筛查的全自动深度学习系统

阅读:1

Abstract

BACKGROUND: Osteoporosis, a disease stemming from bone metabolism irregularities, affects approximately 200 million people worldwide. Timely detection of osteoporosis is pivotal in grappling with this public health challenge. Deep learning (DL), emerging as a promising methodology in the field of medical imaging, holds considerable potential for the assessment of bone mineral density (BMD). This study aimed to propose an automated DL framework for BMD assessment that integrates localization, segmentation, and ternary classification using various dominant convolutional neural networks (CNNs). METHODS: In this retrospective study, a cohort of 2,274 patients underwent chest computed tomography (CT) was enrolled from January 2022 to June 2023 for the development of the integrated DL system. The study unfolded in 2 phases. Initially, 1,025 patients were selected based on specific criteria to develop an automated segmentation model, utilizing 2 VB-Net networks. Subsequently, a distinct cohort of 902 patients was employed for the development and testing of classification models for BMD assessment. Then, 3 distinct DL network architectures, specifically DenseNet, ResNet-18, and ResNet-50, were applied to formulate the 3-classification BMD assessment model. The performance of both phases was evaluated using an independent test set consisting of 347 individuals. Segmentation performance was evaluated using the Dice similarity coefficient; classification performance was appraised using the receiver operating characteristic (ROC) curve. Furthermore, metrics such as the area under the curve (AUC), accuracy, and precision were meticulously calculated. RESULTS: In the first stage, the automatic segmentation model demonstrated excellent segmentation performance, with mean Dice surpassing 0.93 in the independent test set. In the second stage, both the DenseNet and ResNet-18 demonstrated excellent diagnostic performance in detecting bone status. For osteoporosis, and osteopenia, the AUCs were as follows: DenseNet achieved 0.94 [95% confidence interval (CI): 0.91-0.97], and 0.91 (95% CI: 0.87-0.94), respectively; ResNet-18 attained 0.96 (95% CI: 0.92-0.98), and 0.91 (95% CI: 0.87-0.94), respectively. However, the ResNet-50 model exhibited suboptimal diagnostic performance for osteopenia, with an AUC value of only 0.76 (95% CI: 0.69-0.80). Alterations in tube voltage had a more pronounced impact on the performance of the DenseNet. In the independent test set with tube voltage at 100 kVp images, the accuracy and precision of DenseNet decreased on average by approximately 14.29% and 18.82%, respectively, whereas the accuracy and precision of ResNet-18 decreased by about 8.33% and 7.14%, respectively. CONCLUSIONS: The state-of-the-art DL framework model offers an effective and efficient approach for opportunistic osteoporosis screening using chest CT, without incurring additional costs or radiation exposure.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。