The Stability and Repeatability of Spontaneous Sympathetic Baroreflex Sensitivity in Healthy Young Individuals

健康青年个体自发性交感神经压力反射敏感性的稳定性和重复性

阅读:1

Abstract

Spontaneous sympathetic baroreflex sensitivity (BRS) is a valuable tool for assessing how well the baroreflex buffers beat-to-beat changes in blood pressure. However, there has yet to be a study involving appropriate statistical tests to examine the stability of sympathetic BRS within an experimental session and the repeatability between separate sessions. The aim of this study was to use intra-class correlations, ordinary least products regression, and Bland-Altman analyses to examine the stability and repeatability of spontaneous sympathetic BRS assessment. In addition, the influence of recording duration on values of BRS was assessed. In eighty-four healthy young individuals (49 males, 35 females), continuous measurements of blood pressure, heart rate and muscle sympathetic nerve activity (MSNA) were recorded for 10 min. In a subgroup of 13 participants (11 male, 2 female) the measurements were repeated on a separate day. Sympathetic BRS was quantified using MSNA burst incidence (BRS(inc)) and total MSNA (BRS(total)) for the first 5-min period, the second 5-min period, and a 2-min segment taken from the second 5-min period. Intra-class correlation coefficients indicated moderate stability in sympathetic BRS(inc) and BRS(total) between the first and second 5-min periods in males (BRS(inc)r = 0.63, BRS(total)r = 0.78) and females (BRS(inc)r = 0.61, BRS(total)r = 0.47) with no proportional bias, but with fixed bias for BRS(inc) in females. When comparing the first 5-min with the 2-min period (n = 76), the intra-class correlation coefficient indicated poor to moderate repeatability in sympathetic BRS(inc) and BRS(total) for males (BRS(inc)r = -0.01, BRS(total)r = 0.70) and females (BRS(inc)r = 0.46, BRS(total)r = 0.39). However, Bland-Altman analysis revealed a fixed bias for BRS(total) in males and proportional bias for BRS(total) in females, with lower BRS values for 5-min recordings. In the subgroup, intra-class correlations indicated moderate repeatability for measures of BRS(inc) (9 male, 2 female, r = 0.63) and BRS(total) (6 male, 2 female, r = 0.68) assessed using 5-min periods recorded on separate days. However, Bland-Altman analysis indicated proportional bias for BRS(inc) and fixed bias for BRS(total). In conclusion, measures of spontaneous sympathetic BRS are moderately stable and repeatable within and between testing sessions in healthy young adults, provided that the same length of recording is used when making comparisons.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。