Network analysis of spread of SARS-CoV-2 within dialysis clinics: A multi-center network analysis

SARS-CoV-2在透析诊所内传播的网络分析:一项多中心网络分析

阅读:1

Abstract

BACKGROUND: In-center hemodialysis entails repeated interactions between patients and clinic staff, potentially facilitating the spread of COVID-19. We examined if in-center hemodialysis is associated with the spread of SARS-CoV-2 between patients. METHODS: Our retrospective analysis comprised all patients receiving hemodialysis in four New York City clinics between March 12th, 2020, and August 31st, 2022. Treatment-level clinic ID, dialysis shift, dialysis machine station, and date of COVID-19 diagnosis by RT-PCR were documented. To estimate the donor-to-potential recipient exposure ("donor" being the COVID-19 positive patient denoted as "COV-Pos"; "potential recipient" being other susceptible patients in the same shift), we obtained the spatial coordinates of each dialysis station, calculated the Euclidean distances between stations and weighted the exposure by proximity between them. For each donor, we estimated the donor-to-potential recipient exposure of all potential recipients dialyzed in the same shift and accumulated the exposure over time within the 'COV-Pos infectious period' as cumulative exposures. The 'COV-Pos infectious period' started 5 days before COVID-19 diagnosis date. We deployed network analysis to assess these interactions and summarized the donor-to-potential recipient exposure in 193 network diagrams. We fitted mixed effects logistic regression models to test whether more donor-to-potential recipient exposure conferred a higher risk of SARS-CoV-2 infection. RESULTS: Out of 978 patients, 193 (19.7%) tested positive for COVID-19 and had contact with other patients during the COV-Pos infectious period. Network diagrams showed no evidence that more exposed patients would have had a higher chance of infection. This finding was corroborated by logistic mixed effect regression (donor-to-potential recipient exposure OR: 0.63; 95% CI 0.32 to 1.17, p = 0.163). Separate analyses according to vaccination led to materially identical results. CONCLUSIONS: Transmission of SARS-CoV-2 between in-center hemodialysis patients is unlikely. This finding supports the effectiveness of non-pharmaceutical interventions, such as universal masking and other procedures to control spread of COVID-19.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。