Application of an Acoustic Doppler Velocimeter to Analyse the Performance of the Hydraulic Agitation System of an Agricultural Sprayer

应用声学多普勒测速仪分析农业喷雾器液压搅拌系统的性能

阅读:1

Abstract

An acoustic Doppler velocimeter (ADV) was used to analyse the impact of an agricultural sprayer's agitation system settings on fluid velocities inside the tank. A 3000 L capacity sprayer equipped with a 4-nozzle hydraulic agitation system was used. ADV measurements were carried at 32 points inside the tank under the following settings: circuit pressures of 8, 10, or 12 bar; water level in the tank of 1000, 2000, or 3000 L; 2 or 4 active nozzles. An agitation test with a concentration of 0.4% copper oxychloride was employed to analyse the concentration of active matter as a function of tank fill level and number of active nozzles. All parameters significantly affected the fluid velocity, which increased with increasing pressure, but decreased with increasing water level in the tank and an increased number of active nozzles. Concentration tests showed greater active matter concentrations when higher velocities were recorded by the ADV. The ADV was shown to be a useful tool for the rapid assessment of fluid velocities; in the future, it could be used to validate the design of agitation systems, and to estimate their capacity to ensure an adequate level of active matter concentration in the fluid.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。