An Interdigital Electrode Probe for Detection, Localization and Evaluation of Surface Notch-Type Damage in Metals

用于检测、定位和评估金属表面缺口型损伤的叉指电极探针

阅读:1

Abstract

Available microwave notch-type damage detection sensors are typically based on monitoring frequency shift or magnitude changes. However, frequency shift testing needs sweep-frequency data that make scanning detection becomes difficult and time-consuming. This work presents a microwave near-field nondestructive testing sensor for detecting sub-millimeter notch-type damage detection in metallic surfaces. The sensor is loaded with an interdigital electrode element in an open-ended coaxial. It is simple to fabricate and inexpensive, as it is etched on the RC4003 patch by using printed circuit board technology. The detection is achieved by monitoring changes in reflection amplitude, which is caused by perturbing the electromagnetic field around the interdigital structure. The proposed sensor was tested on a metallic plate with different defects, and the experimental results indicated that the interdigital electrode probe can determine the orientation, localization and dimension of surface notch-type damage.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。