Ten-Fold Elevation of Chromogranin A Level Unrelated to a Neuroendocrine Tumor: A Case Report of the Diagnostic Interference of Proton Pump Inhibitors

与神经内分泌肿瘤无关的嗜铬粒蛋白A水平升高十倍:质子泵抑制剂对诊断的干扰病例报告

阅读:1

Abstract

Chromogranin A (CgA) is a well-known biomarker for neuroendocrine tumors (NETs). However, due to its non-specificity, a proper assessment of CgA test results requires a detailed knowledge of the factors, conditions, and medications influencing its serum concentration. We describe a case of a 61-year-old patient presenting with a mass suspicious of a gastrointestinal NET and an exceedingly high level of serum CgA persistent after mass resection. Following a thorough review of patient's medical history and clinical presentation, along with radiographic and pathological findings, no evidence of a NET was detected. A trial of proton-pump inhibitor (PPI) withdrawal led to a dramatic normalization of CgA level, marking it as the culprit causing this tumor marker elevation. This case highlights the significant impact of PPI use on CgA level, and should incentivize clinicians to provide proper education to patients prior to testing.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。