Secondary Interface Echoes Suppression for Immersion Ultrasonic Imaging Based on Phase Circular Statistics Vector

基于相位圆统计矢量的浸没式超声成像二次界面回波抑制

阅读:1

Abstract

Immersion ultrasonic phased array imaging technology offers great advantages, particularly in coupling and automatic detection of industrial non-destructive testing (NDT). To suppress the influence of secondary interface echoes in the immersion ultrasonic phased array imaging, a novel phase circular statistics vector (PCSV) weighting method is proposed in this paper. Firstly, the PCSV factor matrix is established according to the phase consistency of the echo signals. Secondly, due to the higher phase coherence of the defect echo, the PCSV factor matrix is used to weight the TFM image to suppress the secondary interface echo. The result shows the secondary interface echoes are effectively suppressed in the total focusing method (TFM) image on a 0~40 dB scale. It is also shown that PCSV weighting could not only suppress the secondary interface echoes but also improved the image quality in terms of SNR and lateral resolution by comparing with traditional TFM.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。