Frequency Response of a Six-Electrode MET Sensor at Extremely Low Temperatures

六电极MET传感器在极低温下的频率响应

阅读:1

Abstract

Four-electrode electrochemical cells are widely used for signal conversion in molecular-electronic transfer (MET) motion sensors. The most used ACCA (anode-cathode-cathode-anode) configuration has proven its performance and usefulness for obtaining a superior conversion factor and a wider frequency range over standard geophones at room temperature. However, the MET sensor conversion factor decreases a thousand-fold or more when the temperature drops from room temperature to 233 K. In the design suggested is this paper, a pair of additional gate (G) electrodes has been added outside the standard ACCA cell. An experimental study of the temperature behavior of the resulting G-ACCA-G six-electrode configuration showed that the effects of temperature changes on the cell conversion factor are 5.2 times weaker compared with the standard ACCA configuration.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。