Stability of Proximal Femoral Osteotomies in Pediatric Bone Models Fixed with Flexible Intramedullary Nails and Evaluated by the Finite Element Method

采用有限元法评估儿童骨模型中近端股骨截骨术在柔性髓内钉固定下的稳定性

阅读:1

Abstract

Objective  To evaluate the stability of osteotomies created in the subtrochanteric and trochanteric regions in a pediatric femur model fixed by flexible intramedullary rods. Method  Tomographic sections were obtained from a pediatric femur model with two elastic titanium rods and converted to a three-dimensional model. This model created a mesh with tetrahedral elements according to the finite element method. Three virtual models were obtained, and osteotomies were performed in different regions: mediodiaphyseal, subtrochanteric, and trochanteric. A vertical load of 85N was applied to the top of the femoral head, obtaining the displacements, the maximum and minimum main stress, and the equivalent Von Mises stress on the implant. Results  With the applied load, displacements were observed at the osteotomy site of 0.04 mm in the diaphyseal group, 0.5 mm in the subtrochanteric group, and 0.06 mm in the trochanteric group. The maximum stress in the diaphyseal, subtrochanteric, and trochanteric groups was 10.4 Pa, 7.52 Pa, and 26.4 Pa, respectively. That is around 40% higher in the trochanteric group in regards to the diaphyseal (control). The minimum stress of the bone was located in the inner cortical of the femur. The equivalent Von Mises stress on the implants occurred at osteotomy, with a maximum value of 27.6 Pa in the trochanteric group. Conclusion  In both trochanteric and subtrochanteric osteotomies, fixation stability was often lower than in the diaphyseal model, suggesting that flexible intramedullary nails are not suitable implants for proximal femoral fixations.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。