Evaluation of the EMBOPIPE flow diverter device: in vivo and in vitro experiments

EMBOPIPE 血流导向装置的评估:体内和体外实验

阅读:1

Abstract

BACKGROUND: Although flow diverter device (FDD) has brought revolutionized advances in endovascular treatment of intracranial aneurysms, it also presents considerable drawbacks as well, as the innovation for novel device has never stopped. This preclinical research aims to evaluate the safety and efficacy of a newly developed FDD, the EMBOPIPE, through in vivo and in vitro experiments. METHODS: Aneurysms were induced in 20 New Zealand white rabbits which were randomized to three follow-up groups according to the time elapsed after EMBOPIPE implantation (28, 90, and 180 days). Additional EMBOPIPEs were implanted in the abdominal aorta to cover the renal artery in nine rabbits. Angiography was performed immediately after device placement in all groups. Aneurysm occlusion, patency of renal arteries, and pathological outcomes were assessed. For the in vitro experiments, we measured the thrombogenic potential of EMBOPIPEs (n = 5) compared with bare stents (n = 5) using the Chandler loop model. Evaluation indicators were the platelet counts, macroscopic observations and scanning electron microscopy. RESULTS: EMBOPIPEs were successfully deployed in 19 of 20 rabbit aneurysms (95.0%). The rates of complete or near-complete aneurysm occlusion were 73.3%, 83.3%, and 100% in the 28-, 90-, and 180-day groups, respectively. All renal arteries covered by EMBOPIPEs remained patent, and the mean difference in renal artery diameter before and after the device placement in the three groups was 0.07 mm, 0.10 mm, and 0.10 mm, respectively (p = 0.77). Renal pathology was normal in all cases. The pathological findings of the aneurysms were as follows: thickened and adequate neointimal coverage at the aneurysm neck, minimal inflammatory response, near-complete smooth muscle cell layer, and endothelialization along the device. In vitro experiments showed that the platelet counts were significantly higher in EMBOPIPE blood samples than in bare stent samples and that platelet adhesion to the device was lower in the EMBOPIPE stent struts compared with bare stent struts through macroscopic observations and scanning electron microscopy. CONCLUSIONS: The EMBOPIPE can achieve high rates of aneurysm occlusion while maintaining excellent branch artery patency. It exhibited wonderful pathological results. This novel device with phosphorylcholine surface modification could reduce platelet thrombus attached to the stent struts.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。