Low-Cost Device for Measuring Wastewater Flow Rate in Open Channels

用于测量明渠废水流量的低成本装置

阅读:1

Abstract

This research paper describes the development of a low-cost device for measuring wastewater flow rates in open channels, a significant advancement enabled by the evolution of microcomputers and processing techniques. A laboratory setup was constructed to validate the device's accuracy against a standard flow measurement method, optimizing key parameters to achieve a linear relationship between detected and set flow rates, while considering hardware limitations and energy efficiency. The central focus of the research was developing a method to measure the velocity of contaminated fluid using ultrasonic signals, employing the cross-correlation method for signal delay analysis in a stochastic environment. This was complemented by a procedure to measure fluid levels, also based on ultrasonic signals. The device's reliability was assessed through repeatability and uncertainty measurements, confirming its accuracy with an extended uncertainty not exceeding an average of 3.47% for flows above 40 L/min. The device has potential to provide valuable data on the operational dynamics of sanitary networks, crucial for developing and calibrating simulation models.