OBJECTIVE: To evaluate the effect of deep learning reconstruction algorithm combined with smart metal artifact reduction (DLMAR) on the quality of abdominal CT images in critically ill patients who are unable to raise their arms and require electrocardiographic (ECG) monitoring. METHODS: A total of 102 patients were retrospectively enrolled. All subjects were critically ill patients who were unable to raise their arms and required ECG monitoring. Images were reconstructed using 6 algorithms, including filtered back projection (FBP), iterative reconstruction (IR), deep learning (DL), FBP combined with smart metal artifact reduction (FBPMAR), adaptive statistical iterative reconstruction-V combined with smart metal artifact reduction (IRMAR), and DLMAR. A quantitative analysis of CT values, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) was conducted in regions without metal artifacts and regions with metal artifacts in the liver, as well as the tissues, including those from the liver, spleen, pancreas, and aorta, between the two arms. Qualitative analysis of electrode metal artifacts, the visualization of the structures between the two arms, and image noise was performed with a 5-point scoring system (1=worst and 5=best). RESULTS: In the regions of the liver with metal artifacts, there was a significant difference between the CT values of the DLMAR group ([98.5±9.8] Hounsfield units [HU]) and those of the FBP group ([73.7±5.6] HU), the IR group ([75.3±7.5] HU), and the DL group ([66.3±11.4] HU) (P<0.01). There was no significant difference between the CT values of the DLMAR group and those of the FBPMAR group ([99.8±4.8] HU) and the IRMAR group ([99.6±3.4] HU) (P>0.05). The noise of the DLMAR group was found to be significantly lower than that of the other groups (P<0.01). Furthermore, the SNR and CNR of the DLMAR group were also found to be higher than those of the other groups (P<0.01). In the tissue region between the two arms, the differences in CT values among the six groups were not statistically significant (P>0.05). The noise of the DLMAR group was lower than those of the other groups (P<0.01), and the SNR and CNR of the DLMAR group were higher than those of the other groups (P<0.01). In terms of the removal of metal artifacts, the scores of the FBPMAR, IRMAR, and DLMAR groups (4.27±0.32, 4.44±0.34, and 4.61±0.28, respectively) were higher than those of the FBP, IR, and DL groups (1.36±0.54, 1.32±0.45, and 1.24±0.46, respectively) (P<0.01). The DLMAR group also had a higher score of 4.62±0.37 in the visualization of structures between the two arms and 4.53±0.39 in the noise reduction of images, both of which were higher than those of the other groups (P<0.01). CONCLUSION: DLMAR reduces artifacts, decreases noise, and improves the quality of abdominal CT imaging in critically ill patients who are unable to raise their arms and require ECG monitoring.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。