Validity and reliability of portable A-mode ultrasound in measuring body fat percentage: A systematic review with meta-analysis

便携式A型超声测量体脂百分比的有效性和可靠性:系统评价和荟萃分析

阅读:1

Abstract

The present Systematic Review with Meta-analysis study aimed to evaluate the validity and reliability of the Portable A-mode Ultrasound (P-US) for measuring body fat percentage (BF%). Only studies with participants of both genders which had assessed BF% using P-US compared to the reference standard were selected. Publications up until May 31, 2022 were searched in the MEDLINE, COCHRANE, Science Direct, Web of Science, LILACS, SciELO, PEDro, SPORT Discus, CINAHL and SCOPUS databases. QUADAS-2 was used to assess the risk of bias in the validity studies and QAREL was used for the methodological quality of reliability studies. The JAMOVI software program synthesized the results, from which the Pearson Correlation Coefficient (r) or the square root of the Multiple Linear Regression Determination Coefficient (R2) were extracted for the validity studies, and the Mean of Errors of the Bland-Altman Test (ME) and the Confidence Interval (95%CI) with Upper and Lower Limits for the reliability studies. A total of 13 studies were included, generating 26 results for the quantitative synthesis, 14 for validity and 12 for reliability. Regarding the validity results, a strong correlation was identified between the equipment (r = 0.870 [0.845-0.895], P<0.001), with moderate and true heterogeneity (I2 = 53.47%, P = 0.003), presenting publication bias. A small effect size was identified regarding the reliability results, overestimating the results due to chance between the devices (ME = 0.207 [-0.798-1.212], P = 0.686), with low heterogeneity also due to chance (I2 = 19.44%, P = 0.253), with no publication bias. All of the evaluated studies showed some violation of the instruments, confirming the high risk of bias and the low methodological quality. There is concern with heterogeneity for the validity results explained by the subgroups' analysis. The P-US associated with anthropometric perimeters satisfactorily measures the BF% with samples greater than 100 participants, and males. The results in the reliability assessment show high agreement and high variability, greatly expanding the confidence interval, which should be viewed with reservations. This review received financial support from the Brazilian Air Force. The study was registered with PROSPERO under the number CRD42020166617.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。